Using Capillary Flows in
MEMS Devices
Capillary flows are commonly encountered in MEMS devices. For example, in BioChip designs lengthy micro channels are often used to deliver liquid solution from one place to another. An inlet channel is connected to a liquid reservoir and surface tension forces pull the liquid into the micro channel (provided the liquid is “wetting” to the chip surface). This page covers some specific applications for FLOW-3D in the analysis of such capillary flows: filling, absorption and switching.

Capillary Absorption
Capillary absorption into the pore of a solid substance occurs because of adhesion between the liquid and the solid. A simple, yet useful, test of absorption has been suggested by Martti Toivakka of Abo Akademi University in Finland. The test pore consists of a1.0 μm wide, two-dimensional channel connected to an expanding throat whose side walls are circular arcs with 1.0 μm radii. In the absence of body forces, surface tension and wall adhesion pull liquid into the channel to a level that depends on the static contact angle between the liquid and solid. The accompanying figures show that FLOW-3D correctly computes the filling level (fluid is red) for any given contact angle.
Capillary Filling
Understanding the capillary filling process is important to chip design. Different geometry of liquid flow pathways may result in different capillary filling behavior including the possibility of entrapping air bubbles, etc. Knowledge of the filling process guides designers in arranging internal structures of the chip such as chambers, binding pillars, splits, valves, etc.

Thermocapillary Switch
A small mass of liquid moved in or out of the path of a light beam can redirect it by refraction or reflection into a different path. This concept is particularly attractive in connection with optical fibers where once a beam enters a fiber it is trapped by internal reflections. To make optical circuits of any complexity, it is necessary to have a “switch” that can redirect light from one fiber to another. One concept that has been proposed is based on thermo-capillarity. A small drop of liquid is placed in a micro channel that intersects a fiber-optic light beam. When the drop is moved along the channel to where the beam must pass through it, the beam is reflected into a different fiber. The drop is moved by differentially heating its two sides. This causes changes in the surface tension in the menisci on either side of the drop such that the drop is pulled toward the cooler end of the channel. The accompanying figure shows a FLOW-3D simulation of a drop of water in a 14mm-wide channel that is being heated at the bottom. An excellent case study addressing the use of FLOW-3D to design optical switches is found in the Microfluidics Tech Papers section, Note #1-03.
Medical Test Strips
Medical test strips used for rapid diagnostics and determination of relevant biomedical parameters have undergone considerable advances in recent years. Far from the conventional strips with absorbent fleece, new precisely-fabricated microchannels, with defined geometric structures, are now possible via Microsystems engineering. Proper geometrical design of these microstructures enables selective control of the capillary-driven flows. FLOW-3D simulation can be used to optimize the designs of these strips.